Where can I find Fieldpoint 6.1

I recently upgraded to LabView 2013 and, since then, I can no longer get my software to communicate with my FieldPoint hardware.  I am using FieldPoint driver version 6.0.11. I've been poking around...

View Article


FI-AO-200 and FI_AI-110

Hi,  I have an alicat mass flow controller (MCR).  I need to wire for both input and output signal.  I have an FI-AI-110 to read in 0-5 V signal and an FI-AO-200 to sent out 4-20mA signal.  The alicat...

View Article


cFP-PWM-520 ch0 was working then stop can not get any PWM signal

I was using the cFP-PWM-520 to control a H-Bridge(with higher current capability). I was getting eraric output of the H-Bridge, while checking I found the +24VDC input into H-Bridge loose an proceded...

View Article

fpga

Hi,How to control sampling speed in cFP-AI-100?Regards,Prasad

View Article

FP1601 connectivity issue, error message: 33162

Hi, I am currently having problem connecting to my FP1601 ethernet interface from the host computer. Here is a little bit of background: There were two ethernet cards on my host computer and the cross...

View Article


What is the function of the FP Write VI?

Hello, I'm currently a beginner getting familiar with LabVIEW. I'm trying to learn to utilize FieldPoint hardware and I came across the FP Write VI. I'm wondering what exactly is the function of this...

View Article

what is the last version of labview to support classic FieldPoint?

what's the last version of labview to support classic FieldPoint? 

View Article

FP TC 120 Output

Hi everyone, I will be using the FP TC 120 module to measure several temperatures using thermocouples. My question is that if I use FP Read to read the output from FieldPoint IO Point In which...

View Article


What's the maximum digital I/O frequency for the NI LabVIEW RIO Evaluation Kit ?

Hi! I'm trying to analyze some sort of sine signal at the frequency of about 3 MHz. Because the analysis should be very precise and fast (about 10 samples per period), I'm needing the maximum digital...

View Article


Can't find subFieldPoint.vi in Labview2013

I have updated my computer to LabVIEW2013 and I need to move a FieldPoint application over to Windows 7.  My old vi says the subFieldPoint vi are no good.  OK, so where are the new ones?  I updated...

View Article

cFP IP Address changes when unplugged

HI, I have a cFP 2200 with 1 AI-110 input module, 1 AO-200 output module, and 1 RLY-423 Relay module. Every time I unplug the power to the cFP system and then plug it back in the IP address changes. I...

View Article

FieldPoint to 9-Pin D-Connector

Hi, I'm wondering if it is possible to use the FP-AI-112 input module to read from a digital power supply that displays flow rates. The manual for the power supply states that it  has 9-Pin D-connector...

View Article

Rigol DG1062

I am using .  I can’t get a Labview driver for this specific function generator. I try the DG4000. I gives me a signal error and can’t figure it out.  Can you please suggest me how to get the Labview...

View Article


FiieldPoint example fails to deploy

Hardware: FP-2015Software: Labview RT 8.2.1, FieldPoint 6.0.6f Software on FP-2015:FieldPoint 6.0.6 - Feb 2010DataSocket for LabVIEW Real-Time 4.4FieldPoint Drivers 6.0.6FieldPoint VI Manager...

View Article

cFP Module ID over Modbus

I have a cFP-1804 base with several modules installed and I'd like to be able to identify which module is in a particualr slot. I'm using Modbus to do all my configuration and data collection. Is there...

View Article


error writing to field point

I am trying to connect Field point  FP-1001 by Ni PCI-485/2 multifuction adaptor . when i start the program by Ni scope i found " ERROR WRITING TO FIELD POINT". i have checekd the pci card and its...

View Article

Image may be NSFW.
Clik here to view.

FieldPoint cFP-1601 and MAX5.6 configuration

Dear All, I would like to share a way to configure the cFP-1601 Ethernet using the MAX 5.6 that doesn't anymore supports this device. The solution is an workaround on the compatibility problem for MAX...

View Article


cfp-ctr-500

Hi, I have recently upgraded a system from fieldpoint modules to compact fieldpoint.I have a cfp-ctr-500 module which I use to generate a pulse output, a terminal count attribute is used to program the...

View Article

How to read USER1 DIP-switch status of a cRIO chassis from FPGA?

How can I  read the status of the DIP switches on a cRio chassis from the FPGA? I am working with a  cRIO 9022.. My idea is to set the system into a "service" mode by setting the USER1 switch to ON and...

View Article

Image may be NSFW.
Clik here to view.

R.I.P. Compact FieldPoint

I knew our favourite automation controller, the cFP-2220, is set to be unavailable from 2016, but for some reason I still expected it to be programmable in LabVIEW 2014. As far as I can see the plug...