Using old Fieldpoint modules with Labview 18+
I have some old Fieldpoint modules I'd like to use, but the support for Fieldpoint stopped at Labview 2016. I'm using version 2018. The modules I'm using are FP-1000, FP-AI-110 as well as FP-DO-401,...
View ArticleIntégration mécanique
Bonjour. Je souhaiterai intégrer un Crio9035 dans la mécanique de ma baie.Pourriez vous me fournir le step de de cet élément (Plan N° 7U296 du 01/04/016) ?Je vous remercie par avance. Claire FEIERSTEIN
View ArticleWarning(?) mark in I/O project view on cFP
Hello, What does warning/error mark next to I/O channel mean? I have never seen that on cFP before and this system was operational. Regards
View ArticlecFP-PWM-520 ch0 was working then stop can not get any PWM signal
I was using the cFP-PWM-520 to control a H-Bridge(with higher current capability). I was getting eraric output of the H-Bridge, while checking I found the +24VDC input into H-Bridge loose an proceded...
View ArticleFP-1601 Issue
Hi folks,I'm trying to configure a replacement FP-1601 ethernet module. Went through the reset procedure. Status LED is flashing about once per second. Activity LED is active flashing and Link and...
View ArticleThermocouples Reading incorrect values
Hey all, I am working on a project that is using LabVIEW and FieldPoint 2015 series to collect thermocouple data using type K thermocouples and FP-TC-120 modules. I didn't write the LabVIEW code or...
View ArticleNew computer running FieldPoint built application not communicating
My old company still uses a temperature logger I designed using National Instruments hardware and software. It has worked flawlessly for more than a decade. The computer that communicates the the NI...
View ArticleOld FieldPoint Software
We have a customer using an old FieldPoint FP-1001, and we are replacing a computer. I found the drivers, but cannot find FieldPoint Explorer. Is there anywhere I can get a copy of this? Thanks
View ArticlecFP-2220
Hi all, i have a cFP-2220 and after a network malfunction it stopped. I recovery it , from MAX , with IP RESET switch and reset it is restarted with a network interface Ip 0.0.0.0 and from max i set IP...
View ArticlecFP-220 Image cloning
Is there a solution to clone a cFP-2220 image? thanks in advantage!
View ArticleNetwork Led on FP1001 module is full bright but no communication
Dear all I am working on an installation with 9 FP1001 modules in an RS485 network. I needed to connect this system to a new device (a Moxa ethernet / RS485 converter) and got it all operating well. I...
View ArticleVI program to log from fieldpoints
Hi All,I'm trying to learn how to program and log data using NI fieldpoints and VI programs. I know fieldpoints are outdated but we have a complete set of fieldpoint modules in our factory without...
View ArticlecFP AI-111 compatibility
Hi, I want to replace the module cFP AI-111 and I have found one (used) that is coming from Australia. Could there be some compatibility issues?
View ArticleFieldPoint data has lost it's calibration quantities.
Hello All,I'm attempting to assist my old employer to get back a FieldPoint application that has worked flawlessly for year, but during a recent power outage, the communication link still works, but...
View ArticlecFP-2110 Led Status Stays Lit
Hi, I am using the cFP-2110 and the cards to collect data from different signal sources. I powered on my device and the status LED was constantly red. All my power connections and voltages were correct...
View ArticlecFP laptop screen damaged
Hello there, just want to preface that I'm newer to compact FieldPoint. So I apologize if I brutalize any terminology. We had a laptop screen that was damaged and it's connected to a cFP controller for...
View ArticlecFP-2200 사용 SOFTWARE가 필요합니다
수고많습니다.대성베스텍 배인한 (010-5598-4284 )입니다. cFP-2200를 사용하고 있습니다.SOFTWARE와 SOFTWARE 사용자 메뉴얼이 필요합니다.부산에서 교육을 받을수 있는 곳이 있다면 알려 주세요.
View ArticlecFP Module ID over Modbus
I have a cFP-1804 base with several modules installed and I'd like to be able to identify which module is in a particualr slot. I'm using Modbus to do all my configuration and data collection. Is there...
View ArticleCFP - 2120 Unrecoverable error
Hello all, I work for a lab that does high temperature testing. We use the CFP system for our data acquistion. Recently, during a new PC setup, while trying to format the CFP-2120, it states there has...
View ArticleData Acquisition from cFP-2120 to Simulink
Hi Everyone, I have a cFP-2120 that I want to use to monitor parameters from a small turbojet engine I'm making. I need to monitor this data using Simulink, but I'm not sure how to do this. The most...