Looking for an FP-RLY-420 to buy
I have a FieldPoint based test system that has a bad channel in a FP-RLY-420 module. Not sure if it is a relay coil or drive circuit issue. I will try to repair later. I need to get this production...
View Articleusers login and MAX configuration
I have searched the site for 3 days and finally found a post titled; "IAK user login and MAX configuration" on 4/21/2009 that asked about the same issue I am having. I am wondering if there is anything...
View Articleissues with cfp AIO 600 output
Hi, I am trying to get cfp AIO 600 to output current, for this I am using the sample VI for the cfp AIO 600. I cannot get current on the output and I have trouble troubleshooting the issue. 1) How...
View ArticleGetting an old fp-1000 back into action
hello everyone,Our situation goes as follows: we have an old fp-1000 device attached to three fp-ai-110 along with some temperature sensors. The overall system, as far as I know, was running smoothly...
View ArticleWhy cant MAX see my cFP1808's?
I have just purchased two cFP1808 chassis but when I try to configure them using MAX, they do not appear under Remote Sysems. I have a direct ethernet connection to the devices using a CAT5 XOVER cable...
View Articleask for a help in a mini project:text to speech
I've been working on a project that should convert a text to speech in arabic language . This program consist to convert each letter from the file(.py type) to a number (correspond unicode) in1D array...
View ArticleIs there a way to simulate a fieldpoint module?
I am looking for a way to simulate a FieldPoint module such as the cFP-AIO-600. I do not have one on hand, but I would like to develop software that uses it. Is this possible?
View ArticleChannel address for field point network modules
Hi all, I have a FP-1000 network module connected to FP-D0-210, FP-A0-210, and FP-AI-110. I am communicating with these modules through Terminal on OS-X; but i can't figure out addresses for...
View ArticlecFP RLY 425 screw terminals
I have a cFP-RLY-425 that is missing its screw terminals and am having a difficult time finding replacements. Any suggestions on where to purchase would be much appreciated.
View ArticleConnection to cFP-AO-210
Dear all, I have a question on how to connect loads to a cFP-AO-210 module. According to the operating manual, the maximum current for the loads connected via an external power supply is 10 mA. Is...
View ArticleError on FieldPoint Module (App Defined #1)
Hey everyone,This error I'm seeing is on an Analog Output module. I can read the channel fine, but when I write to the channel I get an error that the shared variable cannot be found in the library...
View ArticleFTP bounce vulnerability
A customer of ours did a security check on a cFP-2220 from us and came back with a request for an update to fix the ftp server's vulnerability for bonce attacks...
View Articlevoltage buildup on some unconnected AI-112 terminals
HiI have this strange issue that some terminals tend to autobuildup voltage. And some doesn't.Usually it doesn't bother me since the module is measuring correctly when I connect sensors. BUT the...
View ArticleCompact FieldPoint Life cycle
Is there a cFP life-cycle page on the NI site? I thought I saw one before they completely revamped the site, can't find it now.
View ArticleMAX finds one FP 1601 on a sub net but not a second 1601
I have a legacy system using two 1601 controllers operated by a Windows 2000 system We have been forced to remove the Win 2000 system from the company network for security reasons. Prior to removal the...
View Article16-bit Analog Output Module
I currently have a system with two cFP-AI-100 FieldPoint A/D Modules that are accompanied by a cFP-AO-210 Module. They are both 12-bit, but I’m looking to upgrade my system’s resolution with a...
View Articleobtain program from cFP
hello, I am new to LabVIEW. I have a cFP-2100 currently running and I want to edit the program in it. I don't have the original program I only have the exe file is there is a way to get the original...
View Articled3
sir can u please tell me the difference between d3 graph library and labview in dealing with the graph
View ArticleFieldPoint 6.0.6 (obsolete) driver availability
We have a FieldPoint system with a legacy FP-2015 connected to windows PC. The installed FieldPoint driver version is 6.0.6. I believe it is the latest version that supports FP-2015. We would like to...
View ArticlecFP-1808 alternative
Hello,I am trying to figure out if there are any alternatives to a cFP-1808. Will a cFP-2210 with an 8 slot back plane work exactly the same or is there some difference in the 1808? From what I gather...
View Article